Wednesday, November 9, 2011

Measurement of Arsenic in Sea Water by GC PID, #Arsenic_in_Sea_Water, #Knorr,#NSF,#GC_PID,#Arsenic_speciation,#WHOI

Measurement of Arsenic in Sea Water by GC PID, #Arsenic_in_Sea_Water, #Knorr,#NSF,@GC_PID,#Arsenic_speciati...

Testing of Chemical Warfare Agents via GD-PID,#CW-agents,#GC_PID, chemical-warfafe_agents,#PID_Analyzers.#sarin, #soman,#tabun

The testing was done at the University of Helsinki Laboratory. An HNU model GC311 with a PID (10.2 eV). The goal was to test the HNU Systems GC 311 for the verification of Chemical Warfare (CW) agents.


Materials & Methods
The CW-agents investigated in this work are listed in Table 1, The standard solutions of Model compounds were prepared in Methanol by consecutive dilutions of stock solution containing 100 ug/uL in ethyl acetate. Methanol was chosen as the solvent to eliminate a large solvent peak due to the lack of a split valve in the GC311. Methanol is not ionized by the 10.2 eV lamp.


The GC311 was equipped with a photoionization detector (10.2 eV) . The compounds were separated on a fused silica capillary column (phase NBW 311, 15M x 0.53 mm id x 1.5 um film thickness) . The injection volume varied from 2.5- 5uL. Injector/detector temperature was 200C and the oven temperature was 100 C for sarin, soman, tabun and mustard gas and 150C for Lewisite-3.

Results and Discussion.
Figures 1 & 2 show chromatograms of a standard solutions of sarin, soman, tabun and mustard gas at concentration levels of 100, 50, 4 and 1 ng. The detection limit of sarin, soman, tabun and mustard gasis about 1 ng and for mustard gas is 0.5 ng which is about 10 x better than that of the FID run at the same time. The sensitivity of the Lewisite-3 is 0.2 ng because of the 3 double bonds in that compound.





The portable GC311 has been shown to be a powerful instrument for the detection of CW-agents especially for the direct analysis of air samples. The instrument can also be used for the monitoring of incinerator exhaust gases during the destruction period of CW-agents. The analyzer could be more useful for the analysis of liquid samples if a split injector were available.
The GC311 is no longer in production but a new portable GC is available from PID Analyzers, the Model GC312.

Photo GC311 (no longer in production)


Photo GC312 (replacement for GC311)







The work in this report was done with an HNU GC311 shown above. The replacement instrument described in this report is a GC312 manufactured by:

PID Analyers,LLC,
2 Washington Circle,
Sandwich, MA 02563 T 1 774 413 5281 F 1 774 413 5298
url: http://www.hnu.com
Follow our Blogs:
http://gasdanalysis.blogspot.com
http://gcdetectors.blogspot.com
http://analyzersource.blogspot.com
Follow us on Facebook:
http://www.facebook.com/pidanalyzers

Tuesday, October 25, 2011

Review of Photoionization Detection in Gas Chromatography: The fFrst Decade

This was the first review of the photoionization detector 10 years after it was commercialized.


Review of Photo Ionization Detection in Gas Chromatography The First Decade, #Photoionization,#PID Analyzer...

Sunday, October 16, 2011

Review of Photo Ionization Detection in Gas Chromatography: The First Decade, #Photoionization,#PID Analyzers,PID,#PID_in_ gas_chromatography

This is the first review of photoionization in gas chromatography.


Review of Photo Ionization Detection in Gas Chromatography The First Decade, #Photoionization,#PID Analyzer...

Sunday, October 9, 2011

Determination of Water & O2 at Low ppm Levels by GC-FUV

The Far UV absorbance detector that can measure low ppm levels of water and oxygen has been improved by modifying the detector design.




Determination of Water & O2 at Low Ppm Levels by GC FUV

Saturday, September 24, 2011

Capillary Gas chromatographic Analysis with the Far UV (FUV) Detector #GC,#Capillary_GC.#PID Analyzers,#FUV,#ppm,#ppb

Here is an older paper on the Far UV absorbance Detector (FUV) that is a popular download on our website. The FUV can detect water, O2, and inorganic compounds at the same time as organic compounds. at ppm to ppb levels. The FUV sensitivity has been improved and this detector has been reintroduced by
PID analyzers.


Driscoll 1988 Capillary Gas Chromatographic Analysis Withthe Far UV[1]

A schematic of the FUV detector for GC is shown below:


A chromatogram of C1 to C6 hydrocarbons on a thick film capillary column follows:

Saturday, September 17, 2011

Gas Chromatography in Environmental Analysis #PID, #photoionization, #environment, #Gas_Chromatography, #PID, #PID_Analyzers

This chapter describes gas chromatography, GC detectors, GC columns used in environmental analyses, and applications of these techniques for analysis of environmental samples.


Gas Chromatography in Environmental Analysis- Driscoll 2004 L


The work in this chapter could done with a PID Model GC312 shown above. The GC is manufactured by:
PID Analyers, LLC
2 Washington Circle
Sandwich, MA 02563
1 774 413 5281
URL: http://www.hnu.com
Blogs: follow us at:
http://gasanalysis.blogspot.com
http://gcdetectorguy.blogspot.com
http://analyzersource.blogspot.com